Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 334
Filtrar
1.
Dalton Trans ; 53(13): 6031-6040, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38470348

RESUMO

BOLD-100 (formerly IT-139, KP1339), a well-established chemotherapeutic agent, is currently being investigated in clinical trials for the treatment of gastric, pancreatic, colorectal, and bile duct cancer. Despite numerous studies, the exact mode of action is still the subject of discussions. Radiolabeled BOLD-100 could be a powerful tool to clarify pharmacokinetic pathways of the compound and to predict therapy responses in patients using nuclear molecular imaging prior to the therapy. In this study, the radiosyntheses of carrier-added (c.a.) [97/103Ru]BOLD-100 were performed with the two ruthenium isotopes ruthenium-103 (103Ru; ß-, γ) and ruthenium-97 (97Ru; EC, γ), of which in particular the latter isotope is suitable for imaging by single-photon emission computed tomography (SPECT). To identify the best tumor-to-background ratio for diagnostic imaging, biodistribution studies were performed with two different injected doses of c.a. [103Ru]BOLD-100 (3 and 30 mg kg-1) in Balb/c mice bearing CT26 allografts over a time period of 72 h. Additionally, ex vivo autoradiography of the tumors (24 h p.i.) was conducted. Our results indicate that the higher injected dose (30 mg kg-1) leads to more unspecific accumulation of the compound in non-targeted tissue, which is likely due to an overload of the albumin transport system. It was also shown that lower amounts of injected c.a. [103Ru]BOLD-100 resulted in a relatively higher tumor uptake and, therefore, a better tumor-to-background ratio, which are encouraging results for future imaging studies using c.a. [97Ru]BOLD-100.


Assuntos
Antineoplásicos , Neoplasias , Compostos Organometálicos , Radioisótopos de Rutênio , Rutênio , Animais , Camundongos , Humanos , Distribuição Tecidual , Antineoplásicos/farmacologia
2.
Eye (Lond) ; 37(5): 959-965, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35140328

RESUMO

BACKGROUND: To assess the long-term visual outcomes in patients with posteriorly located choroidal melanoma treated with ruthenium plaque brachytherapy between January 2013 and December 2015. METHODS: A retrospective review was conducted on consecutive patients treated with ruthenium plaque brachytherapy for post-equatorial choroidal melanoma with available Snellen visual acuity before and after treatment, and the development and treatment of radiation complications. RESULTS: There were 219 patients with posterior choroidal melanoma treated with ruthenium plaque brachytherapy. Median follow up was 56.5 months, range 12-81 months. Final visual acuity was ≥6/12 in 97 (44.3%) patients, 6/12 to 6/60 in 57 (26.0%), <6/60 in 55 (25.1%) and 10 (4.6%) eyes were enucleated. Radiation maculopathy was the most common radiation complication encountered, occurring in 53 (24.2%) patients. Of these, final visual acuity was 6/12 in 10 patients (18.9%), 6/12 to 6/60 in 26 (49.1%), <6/60 in 16 (30.2%) and 1 eye (1.9%) was enucleated. Twenty-five (47%) with radiation maculopathy were treated with intravitreal anti-angiogenic therapy, 27 (51%) were monitored and one (2%) was treated with scatter photocoagulation. Eyes treated with intravitreal anti-angiogenic therapy had better final vision than those observed or treated with retinal laser (chi-square, p = 0.04). On multivariate analysis, close proximity to the optic nerve and fovea, and large or notched plaque type was associated with final vision worse than 6/12. CONCLUSION: Most patients treated with ruthenium plaque brachytherapy for posterior choroidal melanoma retain 6/60 vision, with almost half retaining 6/12 vision at long term follow up.


Assuntos
Braquiterapia , Neoplasias da Coroide , Degeneração Macular , Melanoma , Doenças Retinianas , Rutênio , Humanos , Braquiterapia/efeitos adversos , Neoplasias da Coroide/radioterapia , Neoplasias da Coroide/complicações , Doenças Retinianas/etiologia , Melanoma/radioterapia , Degeneração Macular/etiologia , Estudos Retrospectivos , Radioisótopos de Rutênio/uso terapêutico , Seguimentos
4.
J Cancer Res Ther ; 19(Suppl 2): S912-S916, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38384078

RESUMO

ABSTRACT: Various treatment modalities are available for treatment of ocular tumors, which include chemotherapy, laser, and radiotherapy (external beam radiation therapy or brachytherapy). Brachytherapy using plaque applicator is preferred over external beam radiation therapy when the tumor is well localized, as this therapy delivers radiation dose to the tumor with lower doses to normal tissues in the vicinity. However, plaque therapy is expensive and beyond the reach of many poor patients in India. The Bhabha Atomic Research Center (BARC) recently introduced an indigenous Ruthenium-106 plaque to make brachytherapy treatment available and affordable to all needy patients in India. In the present case series, we report our experience using the indigenous Ru-106 plaque for the treatment of a spectrum of ocular tumors.


Assuntos
Braquiterapia , Neoplasias Oculares , Melanoma , Humanos , Braquiterapia/efeitos adversos , Neoplasias Oculares/radioterapia , Neoplasias Oculares/tratamento farmacológico , Radioisótopos de Rutênio/efeitos adversos , Melanoma/patologia , Dosagem Radioterapêutica
5.
Brachytherapy ; 21(6): 904-911, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35995724

RESUMO

PURPOSE: To estimate ocular geometry-related inaccuracies of the dosimetric plan in Ru-106 ophthalmic brachytherapy. METHODS AND MATERIALS: Thirty patients with intraocular lesions were treated with brachytherapy using a Ru-106 plaque-shell of inner radius of 12 mm. Magnetic resonance imaging was employed to determine the external scleral radius at tumor site and the tumor margins. A mathematical model was developed to determine the distance between the external sclera and the internal surface of the plaque associated with the tangential application of the plaque on the treated eye. Differences in delivered dose to the tumor apex, sclera and tumor margins as derived by considering the default eye-globe of standard size (external sclera radius = 12 mm) against the individual-specific eye globe were determined. RESULTS: The radius of external sclera at the tumor site was found to range between 10.90 and 13.05 mm for the patient cohort studied. When the patient specific eye-globe/tumor geometry is not taken into account, the delivered dose was found to be overestimated by 8.1% ± 4.1% (max = 15.3%) at tumor apex, by 1.5% ± 2.8% (max = 5.7%) at anterior tumor margin, by 16.6% ± 7.5% (max = 36.4%) at posterior tumor margin and 8.1% ± 3.8% (max = 13.2%) at central sclera of eyes with lower than the default radius. The corresponding dose overestimations for eyes with higher than the default radius was 13.5% ± 4.3% (max = 22.3%), 1.5% ± 2.8% (max = 5.7%), 12.6% ± 4.5% (max = 20.0%), and 15.1% ± 5.0% (max = 24.4%). CONCLUSIONS: The proposed patient-specific approach for Ru-106 brachytherapy treatment planning may improve dosimetric accuracy. Individualized treatment planning dosimetry may prevent undertreatment of intraocular tumors especially for highly myopic or hyperopic eyes.


Assuntos
Braquiterapia , Neoplasias Oculares , Humanos , Radioisótopos de Rutênio/uso terapêutico , Braquiterapia/métodos , Dosagem Radioterapêutica , Neoplasias Oculares/diagnóstico por imagem , Neoplasias Oculares/radioterapia , Neoplasias Oculares/patologia , Imageamento por Ressonância Magnética
6.
BMC Ophthalmol ; 22(1): 309, 2022 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-35842619

RESUMO

BACKGROUND: To report the long-term outcomes of Ru-106 plaque radiotherapy in eyes with uveal melanoma (UM) and to assess the effect of tumor thickness and location on final outcomes. METHODS: Medical records of 234 patients undergoing Ru-106 plaque radiotherapy for UM were reviewed, and the visual outcome, globe preservation, and patient survival were evaluated. The results of 2 groups were compared: 1. between thin (small and medium-sized, thickness < 7 mm, 148 eyes [63.2%]) and thick (thickness ≥ 7 mm, 86 eyes [36.8%]) tumors, and 2. between large (largest basal diameter [LBD] > 12 mm, 109 eyes [46.6%]) and medium/small (LBD ≤ 12 mm, 125 eyes [53.4%]). In addition, a comparison of the juxtapapillary location in 46 eyes (19.7%) versus tumors arising elsewhere and between tumors with and without ciliary involvement in 48 eyes (21.5%) were done. RESULTS: The patients were followed for a median of 54.2 months (range: 6-194.5 months). After adjusting for baseline visual acuity (VA), there was no significant association between final VA and different dimension and tumor location groups. Final globe preservation was 91.9%, and there was no significant difference between different dimension- and ciliary body involvement groups regarding anatomical success rate. The juxtapapillary tumors had lower globe preservation (80.4% vs .94.7%, p = 0.002). The hazard ratio (HR) for enucleation in juxtapapillary tumors was HR = 6.58 (95-CI: 3.84 to 11.21). The overall metastasis rate was 6.8%, with no significant difference in juxtapapillary tumors (4.3% vs.7.4%, p = 0.455). CONCLUSIONS: Ru-106 plaque radiotherapy is an effective treatment for thick and large UM. With this type of treatment, the globe preservation rate is lower in juxtapapillary tumors, but there is no significant difference in the metastasis rate.


Assuntos
Neoplasias Uveais , Humanos , Melanoma , Estudos Retrospectivos , Radioisótopos de Rutênio/uso terapêutico , Neoplasias Uveais/radioterapia
7.
BMC Ophthalmol ; 21(1): 385, 2021 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-34727878

RESUMO

BACKGROUND: To assess the impact of brachytherapy on macular microvasculature utilizing optical coherence tomography angiography (OCTA) in treated choroidal melanoma. METHODS: In this retrospective observational case series, we reviewed the recorded data of the patients with unilateral extramacular choroidal melanoma treated with ruthenium - 106 (106Ru) plaque radiotherapy with a follow-up period of more than 6 months. Automatically measured OCTA retinal parameters were analysed after image processing. RESULTS: Thirty-one eyes of 31 patients with the mean age of 51.1 years were recruited. Six eyes had no radiation maculopathy (RM). From 25 eyes with RM, nine eyes (36%) revealed a burnout macular microvasculature with imperceptible vascular details. Twenty-one non-irradiated fellow eyes from the enrolled patients were considered as the control group. Foveal and optic disc radiation dose had the highest value to predict the burnout pattern (ROC, AUC: 0.763, 0.727). Superficial and deep foveal avascular zone (FAZ) were larger in irradiated eyes in comparison to non-irradiated fellow eyes (1629 µm2 vs. 428 µm2, P = 0.005; 1837 µm2 vs 268 µm2, P = 0.021; respectively). Foveal and parafoveal vascular area density (VAD) and vascular skeleton density (VSD) in both superficial and deep capillary plexus (SCP and DCP) were decreased in all irradiated eyes in comparison with non-irradiated fellow eyes (P < 0.001). Compared with non-irradiated fellow eyes, irradiated eyes without RM had significantly lower VAD and VSD at foveal and parafoveal DCP (all P < 0.02). However, these differences at SCP were not statistically significant. CONCLUSION: The OCTA is a valuable tool for evaluating RM. Initial subclinical microvascular insult after 106Ru brachytherapy is more likely to occur in DCP. The deep FAZ area was identified as a more critical biomarker of BCVA than superficial FAZ in these patients.


Assuntos
Degeneração Macular , Melanoma , Angiofluoresceinografia , Humanos , Melanoma/radioterapia , Pessoa de Meia-Idade , Vasos Retinianos/diagnóstico por imagem , Estudos Retrospectivos , Radioisótopos de Rutênio , Tomografia de Coerência Óptica
8.
BMC Cancer ; 21(1): 1270, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34819035

RESUMO

OBJECTIVE: To assess the long-term prognosis for patients with iris melanomas and compare it with the prognosis for small choroidal melanomas. DESIGN: Retrospective observational case series. METHODS: All patients treated for iris melanomas at a single referral institution between January 1st 1986 and January 1st 2016 were included. Patients treated for small choroidal melanomas during the same period were included for comparison. The cumulative incidence of melanoma-related mortality was calculated. Patient and tumor characteristics and size-adjusted hazard ratio (HR) for melanoma-related mortality were compared between iris and small choroidal melanomas. RESULTS: Forty-five iris melanomas and 268 small choroidal melanomas were included. Twenty-four iris melanomas (53%) had been treated with local resection, 12 (27%) with Ruthenium-106 brachytherapy, 7 (16%) with enucleation and 2 (4%) with proton beam irradiation. Twenty-one (68%), 7 (16%) and 2 (4%) of the iris melanomas were of the spindle, mixed and epithelioid cell types, respectively. Twenty-three patients had deceased before the end of follow-up. Median follow-up for the 22 survivors was 13.3 years (SD 9.4). Patients with iris melanomas were more often asymptomatic at presentation and had a trend towards significantly lower age (59 versus 63 years, Student's T-tests p = 0.057). Further, iris melanomas had significantly smaller basal diameter (5.8 versus 8.0 mm, p < 0.0001) and tumor volume (79 mm3 versus 93 mm mm3, p < 0.0001) but greater thickness (3.0 versus 2.5 mm, p < 0.0001). The cumulative incidence of iris melanoma-related mortality was 5% at 5 years after diagnosis, and 8% at 10, 15 and 20 years. The incidence was not significantly different to small choroidal melanomas (Wilcoxon p = 0.46). In multivariate Cox regression with tumor diameter and thickness as covariates, patients with choroidal melanomas did not have increased HR for melanoma-related mortality (HR 2.2, 95% CI 0.5-9.6, p = 0.29). Similarly, there were no significant survival differences in matched subgroups (Wilcoxon p = 0.82). CONCLUSIONS: There are no survival differences between iris and choroidal melanomas when adjusting for tumor size. The reason for the relatively favorable prognosis of iris melanomas compared to melanomas of the choroid and ciliary body is likely that they are diagnosed at a smaller size.


Assuntos
Neoplasias da Coroide/mortalidade , Neoplasias da Coroide/patologia , Neoplasias da Íris/mortalidade , Neoplasias da Íris/patologia , Melanoma/mortalidade , Melanoma/patologia , Carga Tumoral , Braquiterapia/métodos , Neoplasias da Coroide/terapia , Enucleação Ocular , Feminino , Humanos , Neoplasias da Íris/terapia , Masculino , Melanoma/terapia , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Terapia com Prótons , Estudos Retrospectivos , Radioisótopos de Rutênio/uso terapêutico , Fatores de Tempo
9.
Indian J Ophthalmol ; 69(12): 3469-3472, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34826976

RESUMO

PURPOSE: Plaque therapy is a well-recognized treatment for intraocular tumors. In current study, we aimed to prospectively investigate the short-term effects of ruthenium 106 (Ru-106) plaque therapy on the cornea and ocular surface parameters. METHODS: Twenty-five patients diagnosed with choroidal melanoma which undergone Ru-106 plaque therapy from 2016 to 2018 were included. Tear osmolarity, tear film break-up time, Schirmer test I, fluorescein dye staining based on Oxford staining method; Ocular Surface Disease Index (OSDI) questionnaire and corneal specular microscopy were performed. These tests were assessed preoperatively and then 3 months postoperatively. RESULTS: The mean (±SD) age of subjects was 48.52 ± 15.18 years. The patients were followed for a mean(±SD) period of 3.64 ± 2.40 months. Total mean (+SD) delivered radiation dose to the tumor apex and total received radiation by the sclera was 83.20 ± 26.31 and 640.65 ± 472.69 Gray (Gy), respectively. In longitudinal analysis, OSDI score and Oxford staining score increased significantly (P = 0.002 for both variables) and the prevalence of dry eye disease (DED) increased from 20% preoperatively to 72% at 3 months postoperatively (P = 0.001).The changes in the all specular microscopy parameters were statistically nonsignificant (all P values > 0.05). CONCLUSION: There is a considerable increase in the rate of DED following plaque therapy for the treatment of choroidal melanoma in short-term follow-up. The OSDI questionnaire and fluorescein staining test are valuable tools for early detection of DED postoperatively.


Assuntos
Síndromes do Olho Seco , Neoplasias , Adulto , Córnea , Humanos , Pessoa de Meia-Idade , Radioisótopos de Rutênio , Lágrimas
10.
Brachytherapy ; 20(4): 828-834, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33785279

RESUMO

PURPOSE: Brachytherapy with Ru-106 is widely used for the treatment of intraocular tumors, and its efficacy depends on the accuracy of radioactive plaque placement. Ru-106 plaques are MRI incompatible and create severe metal artifacts on conventional CT scans. Dual-energy CT scans (DECT) may be used to suppress such artifacts. This study examines the possibility of creating fusion images from MRI scans (preoperatively) and DECT scans (with the plaque in place) as a tool for confirming the anatomic accuracy of plaque placement. METHODS AND MATERIALS: Six patients with intraocular lesions (5 with choroidal melanoma and 1 with a retinal vasoproliferative lesion) were included. Fusion images of preoperative MRI scans and DECT scans with the plaque in place were created with the Demo version of the ImFusion suite (ImFusion GmbH, Munchen Germany). Clearance margins between the tumor and plaque edge in axial, transverse, and coronal planes as well as the elevation of the posterior plaque edge from the sclera were recorded and associated with the location of the lesion. RESULTS: Plaque-tumor clearance margins for transverse, sagittal, and coronal planes were higher for anteriorly located lesions (5.13 mm ± 0.11 [5.0-5.2], 5.10 mm ± 0.26 [4.9-5.4], and 5.33 mm ± 0.45 [4.9-5.8] respectively) than for posteriorly located lesions (4.16 mm ± 1.44 [2.5-5.1], 4.13 mm ± 1.42 [2.5-5.1], and 4.2 mm ± 1.21 [2.8-5.0], respectively). The elevation of the posterior plaque edge from the sclera was 0.33 mm ± 0.28 [0-0.5] and 0.63 mm ± 0.60 [0.7-1.2] for posterior and anterior lesions, respectively. CONCLUSIONS: Fusion images between DECT and MRI scans may be used as a tool to confirm the accuracy of Ru-106 plaque placement in relation with the intraocular tumors in ophthalmic brachytherapy.


Assuntos
Braquiterapia , Radioisótopos de Rutênio , Braquiterapia/métodos , Humanos , Imageamento por Ressonância Magnética , Radioisótopos de Rutênio/uso terapêutico , Tomografia Computadorizada por Raios X
11.
Br J Ophthalmol ; 105(1): 57-62, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32430342

RESUMO

BACKGROUND: Episcleral brachytherapy is the most common treatment for medium-sized choroidal melanomas. Although controversial, inadequate brachytherapy dose and dose rates have at least a hypothetical implication on patient survival. METHODS: All patients who received ruthenium-106 or iodine-125 brachytherapy for choroidal melanoma at St. Erik Eye Hospital 1996 to 2016 were included (n=1238). Cox regression hazard ratios for melanoma-related mortality across deciles, quartiles and individual integers of apex radiation doses (Gy) and dose rates (Gy/hour) were calculated, adjusted for tumour size and location. RESULTS: The average radiation dose at the tumour apex ranged from 73.0 Gy in the first decile to 108.6 Gy in the tenth. Decreasing apex dose by 1 Gy increments or by decile or quartile group was not associated with melanoma-related mortality (p>0.2) The average radiation dose rate at the tumour apex ranged from 0.5 Gy/hour in the first decile to 2.8 Gy/hour in the tenth. Similarly, decreasing apex dose rate by 1 Gy/hour increments or by decile or quartile groups was not associated with melanoma-related mortality (p>0.5). CONCLUSION: There are no increased hazards for choroidal melanoma-related mortality after brachytherapy with decreasing doses between 108.6 and 73.0 Gy, or with decreasing dose rates between 2.8 and 0.5 Gy/hour.


Assuntos
Braquiterapia/métodos , Neoplasias da Coroide/radioterapia , Radioisótopos do Iodo/uso terapêutico , Melanoma/radioterapia , Radioisótopos de Rutênio/uso terapêutico , Idoso , Neoplasias da Coroide/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Melanoma/mortalidade , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Dosagem Radioterapêutica , Estudos Retrospectivos , Medição de Risco , Acuidade Visual
12.
Br J Ophthalmol ; 105(5): 648-652, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32586936

RESUMO

INTRODUCTION: Uveal melanoma is most commonly treated with radiotherapy, destroying the tumour cells with adequate safety margins and limiting collateral damage to surrounding structures to preserve maximal vision. We used optical coherence tomography (OCT) to study the effects of radiotherapy on the retina. METHODS: Patients with posteriorly located choroidal melanoma treated with proton beam radiotherapy (PBR) and ruthenium-106 brachytherapy between January 2010 and June 2014 underwent spectral domain OCT. RESULTS: Images of 32 patients following ruthenium-106 brachytherapy and 44 patients following proton beam teletherapy were analysed. Following plaque brachytherapy, an early marked disruption of the outer retinal layers could be observed in 30 cases (94%) with retinal atrophy evident in 26 cases (81%). In contrast, the images from patients who underwent PBR showed subtle outer retinal layer change with 16 cases (36%) showing some inner-outer segment junction disruption by 6 months and 63%  by 24 months with minimal atrophy. In cases with tumours <2 mm from the fovea, the visual loss was significantly less at 6 and 12 months in the proton beam group. CONCLUSION: In comparison to ruthenium-106 plaque brachytherapy, PBR leads to more subtle and slower changes in the outer retinal layers enabling retention of visual function for longer. The difference in dosing regime and dose distribution across the tumour is likely to be causative for this structural differential.


Assuntos
Braquiterapia/métodos , Neoplasias da Coroide/radioterapia , Melanoma/radioterapia , Retina/patologia , Radioisótopos de Rutênio/uso terapêutico , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Coroide/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Melanoma/diagnóstico , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
13.
Acta Ophthalmol ; 99(5): e654-e660, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33340258

RESUMO

BACKGROUND: Current standard treatment procedures for Ruthenium-106 (Ru-106) brachytherapy for choroidal melanomas do not use 3D image-guided treatment planning. We evaluated the potential impact of introducing 3D treatment planning and quantified the theoretical clinical benefits in terms of tumour control probability (TCP) and normal tissue complication probability (NTCP). MATERIALS AND METHODS: Treatment plans for thirty-two patients were optimized using 3D image-guided treatment planning and compared to the original 2D clinical plans. Optimization of plans was done in an image-based treatment planning system by optimizing the plaque position and treatment time such that the entire tumour received the prescribed dose of 100 Gy. TCP and NTCP for 2D clinical plans and optimized 3D image-guided plans were estimated from published outcome prediction models and compared within patients using Wilcoxon signed-rank test. RESULTS: The median minimum tumour dose (D99% ) for 2D clinical plans was 93 Gy (range: 23-158 Gy), corresponding to 5-year TCP of 75% (IQR 61-86%), while median tumour D99% for optimized 3D image-guided plans was 115 Gy (range 103-141 Gy), corresponding to TCP of 82% (IQR 80-84%). This was a statistically significant increase in estimated TCP (median increase in TCP 8% (IQR: -5-23, p = 0.006). While the dose to normal tissue increased somewhat, there was no significant change in NTCP. CONCLUSION: 3D treatment planning theoretically allows for improved tumour dose delivery for Ru-106 brachytherapy of choroidal melanomas, resulting in a significant increase in expected tumour control compared to traditional approaches using 2D calculations. The deliverability of optimized plans, and potential increased risk of late complications, will have to be confirmed in future clinical studies.


Assuntos
Braquiterapia/métodos , Neoplasias da Coroide/radioterapia , Imageamento Tridimensional/métodos , Melanoma/radioterapia , Radioterapia Guiada por Imagem/métodos , Radioisótopos de Rutênio/uso terapêutico , Humanos , Dosagem Radioterapêutica
14.
J Environ Radioact ; 220-221: 106302, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32560890

RESUMO

In this work, we present a method to use the European nuclear emergency response system RODOS for analysis of potential sources of airborne radioactivity of an unknown origin. The method is based on a solution of adjoint equations, without modification of the code of long-range atmospheric dispersion model MATCH used in RODOS. The method has been successfully applied to the Ru-106 accident of 2017. The obtained spatial distribution of the correlation between simulations and measurements which could be achieved with source located in a given place, is in a qualitative agreement with analogous results published in other works. The high correlation is centered on the Ural Mountains; this is explained by a very wide expansion of the plume. However, the location of the maximum correlation obtained in this work is in the northern part of Russia, close to a military test site on Novaya Zemlya. This location is far away from the reprocessing plant Mayak in the South-Eastern Urals mentioned in other investigations as the most probable location of the source. In the results presented here, the correlation at the source location corresponding to the Mayak plant is still quite high (0.49); release inventory from this source of about 300 TBq could explain the observed measurements.


Assuntos
Monitoramento de Radiação , Poluentes Radioativos do Ar , Federação Russa , Radioisótopos de Rutênio
15.
J Environ Radioact ; 220-221: 106304, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32560891

RESUMO

For the first time since the Chernobyl accident, detectable concentrations of ruthenium-106 were measured across Europe in September and October 2017. The source of this radioactive cloud remains unconfirmed. In this paper we present a forensic inverse modelling study to simultaneously estimate the source location, timing and magnitude of the unexpected ruthenium-106 release using 473 measurements of atmospheric concentration. To do this, we introduce a novel method, which estimates the uncertainty in the often unknown transport error using a Markov chain Monte Carlo approach. We corroborate the conclusions of other studies which suggest the source location is in the Southern Ural region of Russia, where the Mayak nuclear complex is located. Assuming that the Mayak nuclear complex is the most plausible release location, the method estimates that 441±13 TBq was released 12:00-18:00 UTC 24 September 2017, assuming a six hour release window.


Assuntos
Monitoramento de Radiação , Europa (Continente) , Liberação Nociva de Radioativos , Federação Russa , Radioisótopos de Rutênio
16.
Int Ophthalmol ; 40(8): 2095-2102, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32361860

RESUMO

PURPOSE: This study evaluates the outcomes of ruthenium-106 (Ru-106) plaque brachytherapy for vasoproliferative tumors (VPTs) of the ocular fundus in a single referral ocular oncology center. METHODS: The clinical charts of all patients diagnosed with VPT who underwent plaque radiotherapy from 2002 to 2017 were reviewed. Clinical features, types of treatment, outcomes and complications were evaluated. RESULTS: Of 46 patients with VPT diagnosis in our ocular oncology clinic, 25 (54.34%) cases were treated with Ru-106 plaque brachytherapy. Eleven patients (44%) were male, and the mean age at the time of diagnosis was 40.92 ± 13.11 years. The mean follow-up time was 47.56 ± 36.87 months. Inferotemporal quadrant was the most common site of the tumor (64.00%). The mean delivered apex and scleral dose was 101.56 ± 6.51 and 412.26 ± 113.66 Gray (Gy), respectively. Initial tumor length, width and thickness were 10.26 ± 3.42, 8.05 ± 2.83 and 4.27 ± 1.10 mm, respectively. The mean tumor thickness decreased to 2.60 ± 0.63 mm, postoperatively. Complete resolution of subretinal fluid around the tumor was achieved in 81.80% of cases. Visual acuity was more than 20/400 in 64% of patients before treatment and 60% of patients at last follow-up. CONCLUSION: Our study showed that Ru-106 plaque radiotherapy is an effective and safe method of treatment in VPTs.


Assuntos
Braquiterapia , Radioisótopos de Rutênio , Feminino , Seguimentos , Humanos , Masculino , Retina , Estudos Retrospectivos , Radioisótopos de Rutênio/uso terapêutico , Resultado do Tratamento , Acuidade Visual
17.
Acta Oncol ; 59(8): 918-925, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32412331

RESUMO

Purpose: Ruthenium-106 (Ru-106) brachytherapy is a common eye-preserving treatment for choroidal melanomas. However, a dose-response model describing the relationship between the actual delivered tumour dose and tumour control has, to the best of our knowledge, not previously been quantified for Ru-106 brachytherapy; we aimed to rectify this.Material and methods: We considered consecutive patients with primary choroidal melanomas, treated with Ru-106 brachytherapy (2005-2014). Dosimetric plans were retrospectively recreated using 3D image-guided planning software. Pre-treatment fundus photographies were used to contour the tumour; post-treatment photographies to determine the accurate plaque position. Patient and tumour characteristics, treatment details, dose volume histograms, and clinical outcomes were extracted. Median follow-up was 5.0 years. The relationship between tumour dose and risk of local recurrence was examined using multivariate Cox regression modelling, with minimum physical tumour dose (D99%) as primary dose metric.Results: We included 227 patients with median tumour height and largest base dimension of 4 mm (range 1-12, IQR 3-6) and 11 mm (range 4-23, IQR 9-13). The estimated 3 year local control was 82% (95% CI 77-88). Median D99% was 105 Gy (range 6-783, IQR 65-138); this was the most significant factor associated with recurrence (p < .0001), although tumour height, combined TTT and Ru-106 brachytherapy, and sex were also significant. The hazard ratio (HR) for a 10 Gy increase in D99% was 0.87 (95% CI 0.82-0.93). Using biological effective dose in the model resulted in no substantial difference in dose dependence estimates. Robustness cheques with D1-99% showed D99% to be the most significant dose metric for local recurrence.Conclusion: The minimum tumour dose correlated strongly with risk of tumour recurrence, with 100 Gy needed to ensure at least 84% local control at 3 years.


Assuntos
Braquiterapia/métodos , Neoplasias da Coroide/radioterapia , Melanoma/radioterapia , Radioisótopos de Rutênio/uso terapêutico , Neoplasias Uveais/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Coroide/patologia , Análise de Dados , Relação Dose-Resposta à Radiação , Feminino , Seguimentos , Humanos , Masculino , Melanoma/patologia , Pessoa de Meia-Idade , Probabilidade , Estudos Retrospectivos , Neoplasias Uveais/patologia , Adulto Jovem
18.
Radiat Prot Dosimetry ; 189(4): 497-504, 2020 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-32462197

RESUMO

Airborne radioruthenium, as a result of an accidental release, presents a risk for occupational and public exposure. In fall 2017, a detection of 106Ru was reported by the European atmospheric radioactive contamination monitoring networks. We investigated the daily specific total beta activity of PM10 particle fractions samples. The presented method enables indirect determination of airborne 106Ru activity concentration from total beta activity, in case 106Ru was confirmed as single excess radiological pollutant. This allows for daily measurements and time-resolved 106Ru activity concentration data. We estimated the indicative committed effective dose due to 106Ru inhalation for the Croatian population during the exposure period. Although the estimated dose value of ~169.7 nSv, for ~6-d duration of ruthenium air pollution, was very low, it was ~40 times higher than the value for Hinh from inhalation of other radionuclides (90Sr + 137Cs + 40K + 7Be).


Assuntos
Radioisótopos de Césio , Radioisótopos de Rutênio , Berílio , Radioisótopos , Radioisótopos de Rutênio/análise , Radioisótopos de Estrôncio
19.
Phys Med ; 73: 1-7, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32278254

RESUMO

PURPOSE: To investigate the potential of dual energy CT (DECT) to suppress metal artifacts and accurately depict episcleral brachytherapy Ru-106 plaques after surgical placement. METHODS: An anthropomorphic phantom simulating the adult head after surgical placement of a Ru-106 plaque was employed. Nine DECT acquisition protocols for orbital imaging were applied. Monochromatic 140 keV images were generated using iterative reconstruction and an available metal artifact reduction algorithm. Generated image datasets were graded by four observers regarding the ability to accurate demarcate the Ru-106 plaque. Objective image quality and visual grading analysis (VGA) was performed to compare different acquisition protocols. The DECT imaging protocol which allowed accurate plaque demarcation at minimum exposure was identified. The eye-lens dose from orbital DECT, with and without the use of radioprotective bismuth eye-shields, was determined using Monte Carlo methods. RESULTS: All DECT acquisition protocols were judged to allow clear demarcation of the plaque borders despite some moderate streaking/shading artifacts. The differences between mean observers' VGA scores for the 9 DECT imaging protocols were not statistically significant (p > 0.05). The eye-lens dose from the proposed low-exposure DECT protocol was found to be 20.1 and 22.8 mGy for the treated and the healthy eye, respectively. Bismuth shielding was found to accomplish >40% reduction in eye-lens dose without inducing shielding-related artifacts that obscure plaque delineation. CONCLUSIONS: DECT imaging of orbits after Ru-106 plaque positioning for ocular brachytherapy was found to allow artifact-free delineation of plaque margins at relatively low patient exposure, providing the potential for post-surgery plaque position verification.


Assuntos
Braquiterapia/instrumentação , Órbita/diagnóstico por imagem , Imagens de Fantasmas , Radioterapia Guiada por Imagem/instrumentação , Radioisótopos de Rutênio/uso terapêutico , Esclera/efeitos da radiação , Tomografia Computadorizada por Raios X , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Metais , Esclera/diagnóstico por imagem
20.
Ophthalmologica ; 243(4): 303-315, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31940652

RESUMO

PURPOSE: To describe changes in blue-light fundus autofluorescence (FAF) and corresponding alterations in optical coherence tomography (OCT) within the irradiation field after ruthenium-106 brachytherapy (RBT) for choroidal melanoma. METHODS: Consecutive patients with choroidal melanoma were included in a retrospective case series. Patients were treated with RBT at a single institution. As part of their routine examination patients underwent multimodal imaging including ultrasonography, fundus photography, OCT, and FAF imaging (excitation = 488 nm). FAF images were analysed for changes within the irradiation field. RESULTS: 31 patients (mean age 65.7 years) were treated with RBT for unilateral choroidal melanoma. Mean tumour height before therapy was 2.7 mm (SD 1.0). Mean follow-up time was 23.3 months (SD 13.3). Main FAF characteristics attributable to RBT emerged as increased FAF with speckled decreased FAF (FAF mottling) within the irradiation field and a rim of increased FAF at its border. OCT scans demonstrated loss of the ellipsoid zone and the external limiting membrane, thinning of the neurosensory retina, and alterations of the retinal pigment epithelium like clumping, migration, and atrophy. CONCLUSIONS: FAF changes in the irradiation field after RBT of choroidal melanomas follow a characteristic pattern that correlates with distinct OCT alterations. FAF and OCT imaging give additional information to monitor effects of RBT and, therefore, complement multimodal imaging techniques after plaque therapy.


Assuntos
Braquiterapia/métodos , Neoplasias da Coroide/diagnóstico , Angiofluoresceinografia/métodos , Melanoma/diagnóstico , Oftalmoscopia/métodos , Epitélio Pigmentado da Retina/patologia , Radioisótopos de Rutênio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Coroide/radioterapia , Feminino , Fundo de Olho , Humanos , Masculino , Melanoma/radioterapia , Pessoa de Meia-Idade , Epitélio Pigmentado da Retina/efeitos da radiação , Estudos Retrospectivos , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...